Displays
Warning
indicator
Status
Measures
DPF
parked re-
generation
1
The SCR system has experienced an abnormality.
Verify the DTC displayed on the performance monitor and contact your
local KUBOTA Dealer.
The engine output is unrestricted.
After 195 minutes, the engine output will be limited to 50% (limited en-
gine output:
“Lv.1”
).
inhibit
1
The SCR system has experienced an abnormality.
Verify the DTC displayed on the performance monitor and contact your
local KUBOTA Dealer.
The engine output is limited to 80%.
After 120 minutes, the engine output will be limited to 50% (limited en-
gine output:
“Lv.1”
).
inhibit
2
The SCR system has experienced an abnormality.
Verify the DTC displayed on the performance monitor and contact your
local KUBOTA Dealer.
The engine output is limited to 50% (limited engine output:
“Lv.1”
).
After 45 minutes, the engine output will be limited to idle status (limited
engine output:
“Lv.2”
).
inhibit
3
The SCR system has experienced an abnormality.
Verify the DTC displayed on the performance monitor and contact your
local KUBOTA Dealer.
The engine output is limited to idle status (limited engine output:
“Lv.2”
).
inhibit
---
---
Due to low temperatures, the DEF/AdBlue
®
has frozen.
Continue the warm-up operation and the DEF/AdBlue
®
will thaw.
inhibit
---
---
Due to low temperatures, the DEF/AdBlue
®
has frozen. The engine
output is limited to 80%.
Continue the warm-up operation and the DEF/AdBlue
®
will thaw.
inhibit
NOTE :
• The limited engine output level:
The text
“Lv.1”
and
“Lv.2”
displayed next to the icon represents the limited engine output level.
“Lv.1”
(Level 1): Within 50% of max torque and 60% of engine speed.
“Lv.2”
(Level 2): Within engine near idling speed.
• After an error has occurred, it may be necessary for the engine output to become limited to
“Lv.2”
.
Depending on trouble spots and contents, the indicator-prompted warnings and the engine output limits
and timings may vary accordingly.
The SCR warning status (from 1 to 3) represents the severity order of the engine output limitation. If the
SCR system experiences abnormalities, an error code will be displayed, and it may be necessary to limit
the engine output to idle status (
“Lv.2”
).
For example, when a
“ENG P-204F”
error code is displayed, the engine output changes from unrestricted to
“Lv.2”
limited.
• Points after taking measures.
After the engine has stopped and the DEF/AdBlue
®
has drained, if the amount that was refilled is less
than the pre-drain amount, the SCR system may experience a malfunction (
“P20F5”
error code is
displayed).
When the error occurs, turn the key switch to “OFF”, wait for the SCR system to complete the purge
process (this may take several minutes) and then turn the key switch to “ON” again in order to clear the
SCR system malfunction.
• The time displayed on the lower right of the icon represents the minimum time until the limitation begins.
• The 40 hours warning record.
1. Basically, warning and/or inducement reduction cancel when the fault location is repaired.
2. However, if it detects any fault within 40 hours of the restoration, it soon returns to the previous failure
and the timer restarts counting down.
SELECTIVE CATALYTIC REDUCTION (SCR) MUFFLER
OPERATING THE ENGINE
M4N-071, M5N-091, M5N-111
43
Summary of Contents for M4N-071
Page 5: ......
Page 6: ......
Page 21: ...SAFETY LABELS SAFE OPERATION M4N 071 M5N 091 M5N 111 15...
Page 22: ...SAFE OPERATION 16 M4N 071 M5N 091 M5N 111...
Page 23: ...SAFE OPERATION M4N 071 M5N 091 M5N 111 17...
Page 24: ...SAFE OPERATION 18 M4N 071 M5N 091 M5N 111...
Page 26: ...20 M4N 071 M5N 091 M5N 111...
Page 152: ......