4. Operating procedure for regeneration inhibit mode
(1) Parked regeneration switch
(2) DPF inhibit switch
(3) Regeneration indicator
(4) Parked regeneration indicator
(5) Engine rpm increase indicator
(6) Engine warning indicator
Regeneration operating procedure
1. Start the engine.
2. Press the DPF inhibit switch
, and the switch lamp illuminates.
Switch lamp
“ON”
: Regeneration inhibit mode selected.
Switch lamp
“OFF”
: Auto regeneration mode selected.
3. When the parked regeneration indicator
starts flashing:
A specific amount of PM has accumulated in the DPF muffler.
Move the tractor to a safe place and activate the DPF muffler.
(See Operating procedure for parked regeneration on page 39.)
DIESEL PARTICULATE FILTER (DPF) MUFFLER
OPERATING THE ENGINE
M4N-071, M5N-091, M5N-111
37
Summary of Contents for M4N-071
Page 5: ......
Page 6: ......
Page 21: ...SAFETY LABELS SAFE OPERATION M4N 071 M5N 091 M5N 111 15...
Page 22: ...SAFE OPERATION 16 M4N 071 M5N 091 M5N 111...
Page 23: ...SAFE OPERATION M4N 071 M5N 091 M5N 111 17...
Page 24: ...SAFE OPERATION 18 M4N 071 M5N 091 M5N 111...
Page 26: ...20 M4N 071 M5N 091 M5N 111...
Page 152: ......