39
ASSEMBLY INSTRUCTIONS
5. Connect the power beyond hose.
A
Equipment or property damage could result if
instructions are not followed.
A
To verify the hoses, the power beyond line hose
should be installed to the green colored port and also
the pump line should be installed to the orange colored
port of the valve.
A
If the pump line hose and power beyond line hose are
installed incorrectly, the tractor hydraulic pump may
experience malfunction.
C
Connector assembly stay section
1. Fit the connector assembly stay to the main frame with
the bolts and plain washers inserted from the outside
and the nuts and spring lock washers from the inside.
(1) Power beyond line hose with sleeve (hose 5)
(730 mm (28.4 in.), 3/4-UNF and 3/4-UNF)
(2) Valve port marked with a green dot (Power beyond line)
(1) 2-M10 x 60 bolts
(2) 2-M10 nuts
(3) 2-M10 plain washers
(4) 2-M10 spring lock washers
(5) Connector assy stay
(1) Hydraulic hose (Red)
(2) Hydraulic hose (Blue)
(3) Hydraulic hose (Yellow)
(4) Hydraulic hose (White)
(A) Use the holes.