ASSEMBLY INSTRUCTIONS
28
2. Install one lock nut to each cable end. Then route the
cable ends through the valve stay.
A
Check the spool position at first. Distance from center
of the spool holes to end surface of the valve must be
same length as other spools.
A
When assembling the switch section, keeping the self-
level on/off lever downward.
A
The cable with blue tape is for boom section and the
cable with red tape is for bucket section and the cable
with gray tape is for switch section.
3. Install the other lock nuts to the cable ends and adjust
the location of lock nuts so that the cable end hole
aligns with the spool hole. Then connect the cable to
the spools with pins.
4. Loosen the M6 lock nuts of the cable ends. Turn the
cable ends and spools so that the direction of the pins
should be as shown in the figure. Then retighten the
M6 lock nuts.
A
To reposition the cables for correct connections, use
the M16 lock nuts.
(1) Cable (Blue, Boom section)
(2) Cable (Red, Bucket section)
(3) Cable (Gray, Switch section)
(4) 3-M16 lock nuts
(5) Valve stay
(6) Spool (Boom section)
(7) Spool (Bucket section)
(8) Spool (Switch section)
(A) For switch section
(B) Same length (30 mm (1.2 in.))
(1) Cable (Blue, Boom section)
(2) Cable (Red, Bucket section)
(3) Cable (Gray, Switch section)
(4) Valve stay
(5) 3-M16 lock nuts
(6) Spool (Boom section)
(7) Spool (Bucket section)
(8) Spool (Switch section)
(9) 3-Pins
3-Snap pins
(1) 3-M6 lock nuts