Operation
86
Operating modes
The auxiliary port connector is preset at the factory, enabling four operating modes to be selected. Up to six op-
erating modes can be preset.
Whenever the auxiliary port button is pressed the service mode changes by one level.
Select the mode of operation
If the auxiliary port is switched on and a mode of operation has been
selected, the set flow rate in the right auxiliary port connector and
then in the left auxiliary port connector is indicated for few seconds
in the display (2) by pressing the display selector switch (1).
When the starter switch is turned to the RUN position the most-recently used setting is activated.
Auxiliary port not active
Max. flow rate
One way flow
Limited flow volume
Mode 0
Indicator off
Mode 1
Indicator shines
Auxiliary port enable
Mode 2
Indicator blinks
Mode 3
Indicator blinks
Indica-
tor Auxil-
iary port
2
1