- 39 -
Stoker screw 1
Modul 10 (P3)
01-03 22:10:00
Prime switch
On each alarm a black or yellow box will pop up on the display.
In the box the message will tell quite exactly what have caused the alarm.
A alarm example is shown above, and as written the problem is the stoker screw 1, connected to module
10.
The P3 give us the following information:
P: is an expression that the module is missing a phase.
3: is the number on the phase which is missing.
The alarms in the black boxes can only be removed when the supply to the module is re-established and
you afterwards press start.
The yellow alarms disappear by itself when the problem has been solved.
If it against the expectation should happen that there still is an alarm which is not disappeared although
the problem was solved, please restart the system.