8 Servicing/Maintenance
61 of 104
mini-Compacta
2317.886/16-EN
Actions
Required during
Check expansion joints (if any) for wear.
➀
➁
Check the shut-off, drain/vent and check valves for proper functioning and tightness.
➀
➁
Check the collecting tank.
Clean tank from deposits, if any.
In case of major grease deposits in the tank as a result of greasy waste water from industrial
businesses, inform the customer that according to DIN 1986-100 a grease separator must be
installed (upstream of the lifting unit).
Check cover 160 for leakage.
➀
➁
Check fuses.
Size, characteristics, three poles/interlocking device
➀
➁
Replace the fuses after two years of operation (cartridges).
➀
➁
Check the pump/motor for smooth operation.
➀
➁
Check power consumption of motor(s).
➀
➁
Test-run for several start/stop cycles.
➀
➁
Check the alarm equipment to ensure that it functions properly.
➀
➁
Replace the rechargeable battery after 5 years of operation. (
➁
Determine the spare parts requirements, if any.
➀
➁
Advise and/or train operating staff.
➀
➁
Provide new operating manual if necessary.
➀
➁