5 Installation at Site
26 of 104
mini-Compacta
2317.886/16-EN
Before beginning with the installation check the following:
▪
All structural work required has been checked and prepared in accordance with
the dimensions in the outline drawing.
5.3 Installing the sewage lifting unit
WARNING
Insufficient ventilation
Personal injury and damage to property!
▷
Provide proper aeration and ventilation.
▷
For room drainage, a pump sump must be provided.
NOTE
Lifting units should not be installed next to sleeping or living quarters.
NOTE
The anti-vibration mounts of the sewage lifting unit provide adequate insulation
against solid-borne noise.
ü
The name plate data has been compared against the purchase order and the site
data (e.g. supply voltage, frequency, pump operating data, etc.).
ü
The fluid to be handled is an approved fluid. (
ü
The installation room is frost-proof.
ü
All structural work required has been prepared in accordance with the
dimensions stated in the connection example and in EN 12056.
ü
The installation room is of sufficient size. See connection example.
ü
The installation room is adequately lit.
ü
Alarm messages are always recognised in time by the operator. Use an external
alarm transmitter, if required.
1. Place the lifting unit on a level floor. Level it with a spirit level.
2. Place pads 99-3.2 under the feet of tank 591.
3. Use the transport fixture/float protection fixture supplied to secure the sewage
lifting unit firmly to the floor.
In a pre-wall system of mini-CompactaUS40 fasten the transport fixture/float
protection fixture facing the wall to the wall above the sewage lifting unit in
such a way that the sewage lifting unit is firmly pressed against the floor.
1
1
Float protection
4. Then fasten the transport fixture/float protection fixture located at the front to
the floor.