4 Description
22 of 104
mini-Compacta
2317.886/16-EN
▪
Charging time approx. 11 hours when the battery was fully discharged.
4.6.2 Electrical data (LevelControl Basic 2)
NOTE
The rated current must not be exceeded.
Higher currents and power ratings are available on request.
Table 9:
Electrical data of the LevelControl Basic 2 control unit
Characteristic
Value
Nominal operating
voltage
3~ 400 V AC +10 % -15 %
1~ 230 V AC +10 % -15 %
Mains frequency
50 Hz ±2 %
Enclosure
400 V:
IP54
230 V:
IP54
Insulation voltage
500 V AC
Nominal motor current
(standard variants)
Type
BC:
1,6 A / 2,5 A / 4 A / 6,3 A / 10 A
Type
BS:
1,6 A / 2,5 A / 4 A / 6,3 A / 10 A / 14 A / 18 A / 23 A /
25 A / 40 A / 63 A
4.6.2.1 Sensors (LevelControl Basic 2)
Analog level sensor
▪
Input voltage 0 - 5 V
Motor protection
▪
Thermal circuit breaker / bimetal (24 V)
Inputs
▪
1 external alarm input via volt-free contact (24 V)
▪
1 remote acknowledgement via volt-free contact (24 V)
Outputs
▪
1 volt-free signalling output (250 V, 1 A, changeover contact)
▪
1 signalling output for external alarm equipment, e.g. horn, alarm combination,
alarm strobe light (12.6 - 13.2 V)
Rechargeable battery
▪
Mains-independent connection
▪
Power supply for electronics, sensors, alarm equipment
▪
Battery life:
– Approx. 10 hours when supplying the 85 dB(A) piezo buzzer, electronics and
sensors
– Approx. 4 hours when supplying external alarm equipment (e.g. horn, alarm
combination, alarm strobe light)
▪