KSB AMTRONIC R1300 User Instructions Download Page 3

3

AMTRONIC R1300

Utem

Designation

Materials

160

Cover

Polycarbonate  SM60/0

160.1

Distributor  cover

Polycarbonate  SM60/0

163.1

Bonnet

Polycarbonate  SM60/0

191.2

Bonnet

Nickel  plate  brass

198.1

Connection  plate

210.1

Shaft

Polycarbonate  SM60/0

314.1

Friction  washer

Stainless  steel 304L

410.1

Profile  joint

NBR  70

410.2

Profile  joint

NBR  70

410.3

Profile  joint

NBR  70

410.4

Profile  joint

NBR  70

410.5

Profile  joint

NBR  70

410.7

Profile  joint

NBR  70

410.8

Profile  joint

NBR  70

410.11

Profile  joint

NBR  70

412.1

Profile  joint

NBR  70

412.2

O--ring

NBR  70

412.3

O--ring

NBR  70

462.1

Conical  washer

486.1

Ball

Steel

554.1

Washer

Stainless  steel

554.2

Washer

Stainless  steel

554.4

Safety  device

Steel

62.2

Sub- unit adjustable  cam

629

Sub- unit pointer

69- 12

Case

Polycarbonate  SM60/0

74- 6.1

Distribution  plate

74- 7.1

Pneumatic  valve

74- 7.2

Pilot

745.1

Filter

745.2

Filter

Bronze

747.1

Profile  joint check  valve

79- 11

Flow control  1/8”

81- 33

Detection  plate

Steel

81- 84.1

Wiring  diagram

816

Sub- unit angle  sensor

817.1

Packing  gland

82- 2.1

Printed  circuit  board

82- 2.2

Printed  circuit  board

82- 2.3

Printed  circuit  board electro valve 

88- 5

Silencer

Bronze

96- 2.1

Padlockable  plate

Polycarbonate  SM60/0

96- 3

Manual  override

Polycarbonate  SM60/0

890

Base

Polycarbonate  SM60/0

900.1

Screw

A2- 70

900.2

Screw

A2- 70

900.3

Screw

A2- 70

900.4

Screw

A2- 70

900.5

Screw

A2- 70

900.6

Screw

A2- 80

903.1

Plug

916.1

Screwed  plug

916.2

Protection  plug

Rubber

932.1

Circlip

Steel

932.2

Self- locking  retainning  ring

Steel

950.1

Valve  spring

950.2

Lockable  override  spring

Stainless  steel

970.1

Identity  plate

Adhesive  polyester

Summary of Contents for AMTRONIC R1300

Page 1: ...371 8 EN AMTRONIC R1300 Remote indication and control box for pneumatic actuators AMTRONIC R1300 can be fitted directly on all the range ACTAIR DYNACTAIR pneumatic actuators and for any type of VDI VD...

Page 2: ...2 AMTRONIC R1300...

Page 3: ...ub unit adjustable cam 629 Sub unit pointer 69 12 Case Polycarbonate SM60 0 74 6 1 Distribution plate 74 7 1 Pneumatic valve 74 7 2 Pilot 745 1 Filter 745 2 Filter Bronze 747 1 Profile joint check val...

Page 4: ...ned on the cable if just one of the 2 cable glands is used replace the unused cable gland with a watertight plug or seal the cable gland The pneumatic connection must be made according to the product...

Page 5: ...ating time 15 VI Electric connections 16 VI 1 General 16 VI 2 Solenoid valve connection 17 VI 3 Position detection connection 18 VI 3 1 Contacts and standard DPI 18 VI 3 2 Other contacts and detectors...

Page 6: ...0 C Vibrations According to IEC 68 2 6 Test Fc Box Material PC 20 Fiberglass Position signaling By visible pointer on the cover Pneumatic connection 2 times 1 4 gas Electric connection by 2 M20 metall...

Page 7: ...item 11 TORX T20 screwdriver D Remove distribution plate A or B item 8 with both gaskets item 9 E Attach the base item 5 to the actuator with the 4 screws item 6 TORX T20 screwdriver Tightening torqu...

Page 8: ...Remove distribution plate A or B item 7 with its two seals item 5 E Fix the base item 4 to the actuator using 4 M5 screws seals washers item 5 TORX T20 screwdriver Tightening torque 2 5 Nm Check the...

Page 9: ...ate the unit item 3 from the base item 1 by unscrewing the 6 M4 screws item 4 TORX T20 screwdriver C Remove distribution plate A or B item 5 with its two seals item 6 D Fix the base item 1 to the actu...

Page 10: ...10 AMTRONIC R1300 II 4 Linear actuators 1 1 3 4 5 6 10 8 9 11 7 2 12 25 28 27 26 22 23 13 14 15 15 16 17 18 19 20 21 24...

Page 11: ...y 180 according to requirements constraints G Mount the fluted rivet item 15 on the driver item 15 Mount the unit onto the shaft item 1 and tighten with the nut item 17 and washer item 16 H Reposition...

Page 12: ...y N Assembly M Pipe Valve Valve Actuator Amtronic Pipe Actuator Amtronic IV Safety position on loss of current The safety position on loss of current of the AMTRONIC is configured in the factory accor...

Page 13: ...in the last commanded position open or closed Distributor 4 3 center closed Always plate B The safety position in case of power failure is defined by the type of solenoid valve NO Normally Open or NC...

Page 14: ...4 to 115 psi Pressure connection hole P Exhaust connection port marked E equipped with a silencer or connectable to an exhaust network Caution To avoid any premature wear of mechanical parts particula...

Page 15: ...V 2 Mechanical adjustment of the operating time It is possible to adjust the valve operating time by actioning the screws at the base of the box Procedure Adjust the adjustment screws depending on the...

Page 16: ...DYNACTAIR NG 1 to 80 Closed VI Electric connections VI 1 General L AMTRONIC is shipped with 2 IP67 plugs Use of cable glands To access the electrical connection terminals unscrew the 4 TORX screws T2...

Page 17: ...V1 and EV2 solenoid valves refer to chapter VII Pneumatic distribution Electrical characteristics Function Nominal voltage Nominal power Inrush current 3 2 NC 24 VDC 1 W 40 mA 3 2 NC 24 VAC 1 W 118 mA...

Page 18: ...TRONIC R1300 VI 3 Position detection connection VI 3 1 Contacts and standard DPI 1 O and 1 C Additional detection Option Crouzet dry contacts IFM XC0035 detectors Crouzet dry contacts IFM XC0035 detec...

Page 19: ...cycles Resistance to vibrations CEI 60068 2 6 standard 3axi 50g from 10 to 500 Hz Electromagnetic compatibility EN 50081 2 EN 50082 2 Electric connection Welded on circuit Protection level IP 67 Indu...

Page 20: ...20 AMTRONIC R1300 VI 3 2 Other contacts and detectors All mechanical contacts All detectors 2 wires All detectors 3 wires Technical Characteristics available online on the manufacturer website...

Page 21: ...AMTRONIC R1300 21 VI 4 Angle sensor connection option...

Page 22: ...7 5 21 5 36 VDC Output signal 3 6 28 mA Loop resistance Ualim 7 5V 0 02A 0 700 1425 Zero adjustment 4mA 2 4 11 mA Gain adjustment 20mA 16 20 26 mA Temperature range 20 70 C Temperature influence from...

Page 23: ...sed Open Open Open Closed VII 2 Bistable distributor The solenoid valve action depends on the valve safety position when the device has no electrical supply and for the type of actuator in application...

Page 24: ...g DYNACTAIR 50 and 100 opening by air failure end stops on opening DYNACTAIR NG 1 to 80 opening by air failure end stops on opening Safety position on loss of electrical supply EV1 0 EV2 0 EV1 1 EV2 0...

Page 25: ...only be used when the product is powered off The emergency controls are fitted with a locking mechanism Pour activer une commande de secours Push the emergency control Rotate through 90 to lock into p...

Page 26: ...YNACTAIR 1 5 to 25 closing by air failure end stops on closing DYNACTAIR 50 and 100 opening by air failure end stops on opening DYNACTAIR NG 1 to 80 opening by air failure end stops on opening Safety...

Page 27: ...Move the positioner to the end position O or C 3 Remove the position pointer 4 Loosen the central screw of the cam Torx screwdriver T20 5 Adjust triggering of the required contact by turning the colou...

Page 28: ...edback loop gives a reading of 4 mA 4 Position the valve in the open position 5 Adjust the potentiometer 100 until the feedback loop gives a reading of 20 mA 6 Repeat from step 2 until the desired set...

Page 29: ...s are activated but the actuator does not move No air supply Air pressure too high P 8 bar Air pressure too low P 3 bar Valve blocked Actuator blocked or destroyed Distributor obstructed by impurities...

Page 30: ...th cable lug 6 3 Microswitche V3 terminal to weld Detector V3 PNP with cable 3 wires Detector V3 NPN with cable 3 wires Detector V3 CC CA with cable 2 wires Detector V3 NAMUR with cable 2 wires Detect...

Page 31: ...stops on opening O Actair 400 to 1600 Dynactair 1 5 to 25 Closing by air failure FMA Dynactair 1 5 to 25 Opening by air failure OMA Dynactair 50 and 100 Closing by air failure FMA Dynactair 50 and 10...

Page 32: ...Dynactair 50 and 100 FMA FMC 4 2 mono On Off Dynactair 50 and 100 OMA OMC 4 2 mono On Off Dynactair 200 to 800 FMA FMC 4 2 mono On Off Dynactair 200 to 800 OMA OMC 4 2 mono On Off Actair NG 2 to NG 70...

Page 33: ...3 cf POS Actair 400 to 1600 MPMC 4 3 cf POS Dynactair 1 5 to 25 FMA FMC 4 3 cf POS Dynactair 1 5 to 25 OMA OMC 4 3 cf POS Dynactair 50 and 100 FMA FMC 4 3 cf POS Dynactair 50 and 100 OMA OMC 4 3 cf P...

Page 34: ...34 AMTRONIC R1300...

Page 35: ...35 AMTRONIC R1300...

Page 36: ...s leaflet is not contractual and may be amended without notice 8514 8371 8 EN 30 01 2020 AMTRONIC R1300 KSB S A S 4 all e des Barbanniers 92635 Gennevilliers Cedex France Tel 33 1 41 47 75 00 www ksb...

Reviews: