14
AMTRONIC R1300
V - Pneumatic supply
V - 1 Pneumatic connection
Before making any pneumatic connections, check that there are no impurities in the piping, especially when starting the
installation. As a measure of safety, the box is equipped with a filter in the input port in order to prevent the clogging of the
distributor with impurities.
This filter can be cleaned: remove and clean it with solvent or compressed air.
The connection is made on the AMTRONIC box
Operating pressure: 3 to 8 bar (44 to 115 psi)
Pressure connection: hole ”P”
Exhaust connection: port marked ”E” equipped with a silencer or connectable to
an exhaust network.
Caution: To avoid any premature wear of mechanical parts, particularly
for the actuator, it is recommended to use a lubricated air (between 5
and 25 mg/m
3
.
Attention: If severe vibrations are expected or excessive tensile strain
(max. 80 kg) needs to be prevented at the ¼" gas thread connections,
the use of flexible tubing is strongly recommended for pneumatic connection.
To be connected to the
hole 4 of the actuator
Power supply
To be connected to the
hole 2 of the actuator
Exhaust
Power supply
Exhaust
Direct pneumatic connection
Pneumatic connection by piping