VI - 5 Feed-back position (option)
VI - 5 - 1 Electrical characteristics
Recopy characteristics 4- 20 mA passive (2 wires)
Parameters
Minimum
Nominal
Maximum
Unit
Power Supply
7,5
21,5
36
VDC
Output signal
3,6
/
28
mA
Loop resistance [(U
alim
- 7.5V)/0.02A]
0
700
1425
Zero adjustment (4mA)
2
4
11
mA
Gain adjustment (20mA)
16
20
26
mA
Temperature range
-- 20
/
+70
°
C
Temperature influence (from - 20 to +70
°
C)
0,12
0,28
% FS
Hysteresis and dead band
0,05
0,2
% FS
Linearity
0,05
0,2
% FS
10 11
RL = 1425
max for U = 36 VDC
RL = 700
max for U = 21,5 VDC
RL = 0
for U = 7,5 VDC
Power Supply
24 VDC (typ.)