R E P A I R
New NTC wire routing
3. Lead connector through opening in centerpart.
4. Remove NTC wires from cable guides on extraction head.
5. Lead connector through second opening in centerpart.
6. On thermoblock (Z) pull defect NTC sensor (a) out of socket with a pair of pointed
pliers.
For better identifica
tion, NTC wires are
shown in black.
Different NTC wire
routing depending on
machine version.