R E P A I R
Assembly information
•
For handling the new PCB assembly, the service technician must be earthed using
an earthing strap.
•
Insert main PCB (O) with its corners into the guiding slots of the protective cover (Q)
first. Then press main PCB down and lock it in place.
•
Make sure that the main PCB is screwed with the special plastic washer to the
centerpart.
•
For correct wiring refer to electrical wiring diagrams.
The PCB assembly
is sensible to elec-
trostatic discharge - use
safety measures.