Fct. 3.1.0 BASIS.PARAM
This submenu function allows the user to enter the
vortex primary sensor data viz. nominal diameter and
k-factor
APPEARS - Always.
Fct. 3.1.1 NOMINAL.DIA
nominal diameter
Select from the options which DIN/ANSI size
primary is used with the instrument. Options to
choose from are -
l
DN 10 S
l
DN 10
l
DN 15
l
DN 20
l
DN 25
l
DN 40
l
DN 50
l
DN 80
l
DN 100
l
DN150
l
DN 200
l
ANSI 3/8”S
l
ANSI 3/8”
l
ANSI ½”
l
ANSI ¾ ’’
l
ANSI 1’’
l
ANSI 1.5”
l
ANSI 2”
l
ANSI 3”
l
ANSI 4”
l
ANSI 6”
l
ANSI 8”
LIMITS - Not applicable
APPEARS - Always
Fct. 3.1.2 K-FACTOR
k-factor of the primary
Enter the primary constant k-factor value. This value
is stamped on the instrument label in units of
pulses/m3
LIMITS - Limits depend on nominal-dia
NOM.DIA
LOW LIM
HIGH LIM
DN 10S/ANSI 3/8” s
DN 10 / ANSI 3/8”
DN 15 / ANSI ½”
DN 20 / ANSI ¾”
DN 25 / ANSI 1”
DN 40 /ANSI 1.5”
DN 50 / ANSI 2”
DN 80 / ANSI 3”
DN 100 / ANSI 4”
DN 150 / ANSI 6”
DN 200 / ANSI 8”
1370000
490000
290000
107000
42000
12300
6065
1740
775
240
104
1530000
543000
330000
120000
66000
18700
8800
2730
1200
350
163
APPEARS - Always
Fct. 3.2.0 USER DATA
This is submenu level. 3.2.x functions allow selection
of dialogue language, setting of password code 1,
setting of built-in electronic totalizer
Fct. 3.2.1 LANGUAGE
dialogue language
Instrument supports the following choice at present
l
ENGLISH
l
GERMAN
l
FRENCH
Select the language of your choice. Remember that
the selection will have effect when one leaves menu
and respond with
YES
to save changes.
LIMITS - Not applicable
APPEARS - Always
Fct. 3.2.2 ENTRY.CODE.1
entry code 1 password
Select
YES
if password should be checked to access
the menu. Use password to prevent configuration
changes by an unauthorized person. Answering
NO
means password is not required to enter menu.
LIMITS - Not applicable.
APPEARS - Always
Fct. 3.2.3 CODE 1
code 1 password
Enter the actual password which will be required to
access menu afterwards from the point after the
configuration is saved. Password consists of 9
keystrokes of 3 keys in any order. Display shows 9
empty places initially and gets filled with ‘*’ as you
go on entering keystrokes. After 9 keystrokes are over
you are again requested to enter the same sequence
for verification purpose. If verification is found
correct then the function returns to menu level but if
something went wrong, function displays
WRONG
for a couple of seconds (original password, if any,
remains unchanged) and then returns to menu
LIMITS - Not applicable
APPEARS - If
Fct. 3.2.2 ENTRY CODE 1
is
YES
.
Fct. 3.2.4 LOCATION
installation location
Enter an alphanumeric string upto 10 characters to
describe location of installation. This input has no
bearing on the performance of the instrument in any
way, it merely serves as a means of identification.
LIMITS - Not applicable
APPEARS - Always.
Fct. 3.2.5 TOT.VALUE
totalizer value
This function can be used to reset the totalizer (to
zero) or to set the totalizer to any starting value. Two
options are presented.
l
RESET
l
SET.
30