KRAMER ELECTRONICS LTD.
Issue 1-16 May 30, 2017
44
6.3.3
Splicing Width / Splicing Height
This menu defines the dimensions of the LED wall is defined with this menu. The maximum number of
LED screens supported is 16. This function is used in conjunction with the next function.
Settings:
Units Wide: 1, 2, 3, 4
Units High: 1, 2, 3, 4
Default:
Units Wide: 1
Units High: 1
6.3.4
Splicing Horizontal Position (Splicing H-pos) / Splicing Vertical Position (Splicing V-pos)
These settings provide the coordinates of the segment that the unit will process (cut out and resize).
This function is used in conjunction with the previous function.
Settings:
1 to 4 indicating co-ordinates 1,1, to 4,4 for the maximum matrix size of 16
Default :
1, 1
6.3.5
Splicing Setup
In a large LED walls where multiple units are driving different sections of the LED, the sections can be
equal or unequal in size. If the size of the different sections are equal, then the configuration is
standard. For standard configurations the settings discussed so far are sufficient to defined the area
where the output image will be displayed.
If the size of the sections are unequal, then the Advanced splicing setup needs to be enabled in order
to define the size of the area each section.
Standard mode works up to a wall size of 4x4. Advanced mode is limited to a maximum wall size of
2x2.
Settings:
Standard / Advanced
Default :
Standard