KRAMER ELECTRONICS LTD.
Issue 1-16 May 30, 2017
46
6.3.6.2
Standard Splicing - 2x1 Example (Split source)
In this and the rest of the examples, it is assumed that the image arrives at each unit from a single
source, so Splicing Zoom is set to On.
Figure 6: Standard Splicing - 2x1 example (common source)
STEP
MENU ITEM TO MODIFY
Unit-1
Unit-2
1
Output>Display Type>I/O Lock
Source
Source
2
LED Screen Size> Splicing Zoom
On
On
3
LED Screen Size> Splicing Width
2
2
4
LED Screen Size> H-Pos
1*
2
5
LED Screen Size> Right Edge
1320
1320
6
LED Screen Size> Bottom Edge
1440
1440
* Some steps are skipped, because the values are the same as the default settings after factory reset