1.
Launch an Internet browser.
2.
Enter the IP address
of the inverter in the address line of the browser and
confirm with "Enter".
P
The Webserver is called up.
3.
To log in, click on Login and select a user. The
following login data are preset as "Plant owner" as
standard:
User name: pvserver
Password: pvwr
Enter the user name and password.
P
The Webserver's menu opens.
Undertaking settings in the Webserver
After logging in, the settings required can be undertaken
on the inverter or values can be queried via the Web-
server.
TIP
The IP address can be queried in
the inverter menu under "Settings/
Communication/Network settings 2".
Additional entry options in the ad-
dress line of the browser:
n
S and the serial number of the
inverter on the type plate (example:
http://S12345FD323456)
n
Name of the inverter: The inverter
can be assigned a name. This may
be no longer than 15 characters
and may not contain special char-
acters like + - * /... (For example:
http://SWR_5).
IMPORTANT
INFORMATION
The password should be changed
once you have logged in for the first
time under Settings.
The password may consist of no more
than 15 characters and contain the
following characters: a-z, A-Z, 0-9
and _
You need a service code to log in as
an installer. This can be requested
from the Service team.
Should you forget the password, this
can be reset to the default values on
the inverter by going to Service menu
> "Reset web login".