111
8
© 2017 KOSTAL Solar Electric GmbH
Maintenance
8.1 Maintenance and service
Once correctly installed, the inverter runs virtually
maintenance-free.
The following maintenance tasks are to be carried out for
the inverter:
Activity
Interval
Carry out fan test
1)
and check whether the
fans function properly.
Clean fans as required
1x annually or
after an incident
Check cable connections and plugs
1x annually
Clean fans
1x annually
Tab. 9: Maintenance list
If no maintenance work is carried out, this results in an
exclusion of the warranty (see 'Exclusion of warranty' in
our Service and warranty conditions).
1
) The fan test can only be performed in
feed-in mode (green LED lit).
DAMAGE POSSIBLE
Dirty or blocked fans mean that the
inverter is not adequately cooled.
Insufficient cooling of the inverter
may result in output reduction or
the failure of the system.
Always mount inverters in such a
way that falling parts cannot fall
into the inverter through the ven-
tilation grill or mount the optional
fan cover.
2
3
4
6
7
8
9
10
11
1
5