Operation and operating the device
Event
code
LED
display
Type of event
Description/
possible cause
Measure
3049
Internal communica-
tion fault
Internal communication error
Check the internal communica-
tion cables between the individual
PCBs
1
3050
Internal communica-
tion fault
Internal communication error
Check the internal communica-
tion cables between the individual
PCBs
1
3055
Internal system fault
Internal system fault
Restart the device
1
3056
Internal parameteriza-
tion fault
Internal system fault
Contact support
3057
Internal system fault
Internal system fault
Check generator installation/
layout
1
3059
Internal parameteriza-
tion fault
Incorrect parameterization
Country setting may be incorrect.
Contact support
3060
Internal parameteriza-
tion fault
Incorrect parameterization
Contact support
3062
Internal temperature
fault
Internal system fault
No action necessary
1
3063
Internal parameteriza-
tion fault
Internal system fault
Contact support
3076
Information
Internal AC system fault
The AC voltage may be too low.
3079
Internal system fault
Internal system fault
Restart the device
1
3082
Internal system fault
Internal system fault
Contact support
3083
Information
Internal system fault
No action necessary
1
3085
Internal
temperature fault
Overheating of processor
Check installation conditions and
fan
1
3086
Information
Power curtailment due to a grid
fault (increased AC voltage)
Support
1
3087
Internal system fault
Internal system error
Contact support
3088
Internal system fault
Fan unit dirty
Clean fan unit
3093
Internal parameteriza-
tion fault
Incorrect parameterization
Contact support
3094
Internal parameteriza-
tion fault
Incorrect parameterization
Contact support
2
3
4
6
7
8
9
10
11
1