57
4
© 2017 KOSTAL Solar Electric GmbH
Operation and operating the device
4.3 De-energising the inverter
When working on the inverter or the feed cables, the
inverter must be completely de-energised.
It is imperative that these steps are carried out:
1.
Turn the DC switch on the inverter to OFF.
2.
Switch off the AC line circuit breaker.
3.
Switch off the power supply for the S0/AL-Out output
(if present).
4.
Secure the entire voltage supply against being
restarted.
5.
Disconnect all DC connections on the inverter. To do
this, unlock the engaging clips with a screwdriver and
disconnect the plug.
1
1.
2.
Fig. 40: Disconnecting SUNCLIX plug
6.
Wait five minutes until the capacitors of the inverter
have discharged. Allow the device to cool down.
7.
Ensure that all connections are voltage-free.
H
The inverter is de-energised. Work on the inverter or
on the feed cables can now be carried out.
DANGER
RISK OF DEATH DUE TO ELECTRI-
CAL SHOCK AND DISCHARGE!
De-energise the device, secure it
against being restarted and wait
five minutes so that the capacitors
can discharge.
1
Information available online at
www.phoenixcontact.com
2
3
4
6
7
8
9
10
11
1
5