Standard Interfaces – Pin Assignments
Low-active signals are indicated by a minus sign.
9.1.1.
(X1) Power Input Connector
Pin Signal Name
3-pin POWER SUBCON (male)
1
15-30 V DC (input)
2
Shield
3
0 V (input)
9.1.2.
(X7) COM1 Serial Interface RS232
Pin Signal Name
9-pin D-SUB Connector
1
DCD (Data Carrier Detect)
2
RXD (Receive Data)
3
TXD (Transmit Data)
4
DTR (Data Terminal Ready)
5
GND (Signal Ground)
6
DSR (Data Set Ready)
7
RTS (Request to Send)
8
CTS (Clear to Send)
9
RI
(Ring Indicator)
9.1.3.
(X8) DisplayPort
Pin
Signal Name
DisplayPort
Signal Name
Pin
1
ML Lane 0 (p)
GND (ML Lane 0)
2
3
ML Lane 0 (n)
Lane 1 (p)
4
5
GND (ML Lane 1)
Lane 1 (n)
6
7
Lane 2 (p)
GND (ML Lane 2)
8
9
Lane 2 (n)
Lane 3 (p)
10
11
GND (ML Lane 3)
Lane 3 (n)
12
13
AUX SEL#
Pull-down to GND
14
15
AUX CH (p)
GND (AUX CH)
16
17
AUX CH (n)
Hot Plug
18
19
GND (GND_DDC)
3.3V (DDC EEPROM
power
500 mA fused
20
Summary of Contents for FusionClient FC 121
Page 1: ...FusionClient Fusion Client User Guide Rev 1 3 Doc ID 1060 3249 ...
Page 2: ...Fusion Client User Guide Rev 1 3 This page has been intentionally left blank ...
Page 7: ...Fusion Client User Guide Rev 1 3 ...
Page 32: ...FusionClient User Guide Rev 1 3 www kontron com 32 ...
Page 46: ...FusionClient User Guide Rev 1 3 www kontron com 46 flammable materials under the device ...
Page 48: ...FusionClient User Guide Rev 1 3 www kontron com 48 ...
Page 58: ...FusionClient User Guide Rev 1 3 www kontron com 58 ...
Page 70: ...FusionClient User Guide Rev 1 3 www kontron com 70 ...