5/
Installation Instructions
The FusionClient is designed to be mounted in the user’s application by either of the following methods:
Installation in an instrument panel or other cabinets by use of mounting clamps (preferred mounting
method)
Installation by a heavy duty VESA 75/100 compliant mounting system
The FusionClient has to be installed and operated only by trained and qualified
personnel.
We recommend that the mounting procedure is to be carried-out by two persons.
The mounting and operation of the FusionClient is allowed in horizontal (with the
interfaces downwards) and vertical position. Vertical operating position (with the
interfaces to the left or to the right) is only possible when supported by the OS
used.
The unit must be placed such that there is sufficient space for connecting the cables
to the I/O interface connectors.
Leave at least 5 cm (approx. 2") of free space around the unit to prevent the device
from possibly overheating! Do not obstruct the air intake and exhaust openings.
The voltage feeds must not be overloaded. Adjust the cabling and the external
overload protection to correspond with the rated voltage range indicated on the
type label.
The type label is located on the rear left side of the system.
During the system operation, the cover of the computer base must be proper
installed and secured by the corresponding screws.
5.1.
Installation by use of the Mounting Clamps
The mounting clamps with screws (supplied), allow the easy and fast mounting of the FusionClient FC
121/FC 156/
FC 185/FC 215. The outline and mounting drawing can be found on our web site www.kontron.com.
Table 7: FusionClient - Specification for mounting
Dimensions for:
FC 121
FC 156
FC 185
FC 215
Cut-out for mounting to
a wall/panel (W x H)
[mm]
312 x 250 [mm]
(12.28" x 9.84")
398 x 282 [mm]
(15.67" x 11.02")
464 x 321 [mm]
(18.27" x 12.64")
529 x 357 [mm]
(20.83" x 14.06")
Thickness of the
mounting wall/panel
for proper mounting
[mm]
1.5 - 6
Clamp with screws for
mounting the
FusionClient to a
wall/panel
8x
12x
14x
Required Tool
Allen Wrench 2 mm
Proper Torque
Tighten the screws with a torque of 0.7 Nm (start with 0.4 Nm and increase to 0.7
Summary of Contents for FusionClient FC 121
Page 1: ...FusionClient Fusion Client User Guide Rev 1 3 Doc ID 1060 3249 ...
Page 2: ...Fusion Client User Guide Rev 1 3 This page has been intentionally left blank ...
Page 7: ...Fusion Client User Guide Rev 1 3 ...
Page 32: ...FusionClient User Guide Rev 1 3 www kontron com 32 ...
Page 46: ...FusionClient User Guide Rev 1 3 www kontron com 46 flammable materials under the device ...
Page 48: ...FusionClient User Guide Rev 1 3 www kontron com 48 ...
Page 58: ...FusionClient User Guide Rev 1 3 www kontron com 58 ...
Page 70: ...FusionClient User Guide Rev 1 3 www kontron com 70 ...