DC Power Terminal
The FusionClient is delivered with a DC power plug terminal (3-pin Phoenix connector). For DC connection,
prepare the connecting wires using the supplied Phoenix plug terminal: PSC 1,5/ 3-F.
Figure 27: Phoenix power plug terminal
1
3-pin Phoenix plug terminal
2
Cover over the slotted pan head screws
3
Location for inserting the "15-30 V DC
input" wire
4
Location for inserting the
“shield” wire
5
Location for inserting the “0 V
(input)” wire
6.1.1.
Cabling
For the pin assignment Phoenix power plug terminal refer to subsection 9.1.1 “(X1) Power Input
Connector”.
1.
Cut the required length three isolated wires (1 mm
2
) AWG18 and strip each end 5 –7 mm.
2.
Twist the striped wire-ends and provide them with ferrules.
3.
Open the cover (Figure 27, pos. 2) to have access to the slotted pan head screws.
4.
Loosen the slotted pan head screws of the DC plug terminal far enough so that you can insert the end
of the prepared wires.
5.
Insert the wires into the corresponding clamp of the Phoenix plug terminal. Make sure that you have
the right polarity of the connection [refer to Figure 27, Figure 13 or subsection 9.1.1 “(X1) Power Input
Connector”].
6.
Fasten the screws to secure the wires into the clamps of the plug terminal.
7.
Close the cover (Figure 27, pos. 2).
3
2
1
4
5
Summary of Contents for FusionClient FC 121
Page 1: ...FusionClient Fusion Client User Guide Rev 1 3 Doc ID 1060 3249 ...
Page 2: ...Fusion Client User Guide Rev 1 3 This page has been intentionally left blank ...
Page 7: ...Fusion Client User Guide Rev 1 3 ...
Page 32: ...FusionClient User Guide Rev 1 3 www kontron com 32 ...
Page 46: ...FusionClient User Guide Rev 1 3 www kontron com 46 flammable materials under the device ...
Page 48: ...FusionClient User Guide Rev 1 3 www kontron com 48 ...
Page 58: ...FusionClient User Guide Rev 1 3 www kontron com 58 ...
Page 70: ...FusionClient User Guide Rev 1 3 www kontron com 70 ...