![Kontron FusionClient FC 121 User Manual Download Page 55](http://html.mh-extra.com/html/kontron/fusionclient-fc-121/fusionclient-fc-121_user-manual_1996613055.webp)
FusionClient – User Guide (Rev. 1.3)
www.kontron.com
// 55
2.
Ensure that the DC power source is switched off via a disconnecting device (circuit breaker), in order
to ensure that no power is flowing from the external DC power source during the connection
procedure.
3.
Connect at first the wire for the grounding stud” (Figure 12, pos. 11) to an appropriate “common earth”
connection point.
4.
Connect the Phoenix power terminal prepared as described in subsection 6.1.1 ”Cabling” to the DC
input connector (Figure 12, pos. 1, marked X1) of the FusionClient. The DC input connector is located on
the front side and is marked “24 VDC”.
5.
Connect the other ends of the DC power wires to the connections of the DC main power supply. Pay
attention to the polarity of the connections.
6.
Switch on the disconnecting device (circuit breaker) in order to apply voltage to the terminals of the
power wires.
Summary of Contents for FusionClient FC 121
Page 1: ...FusionClient Fusion Client User Guide Rev 1 3 Doc ID 1060 3249 ...
Page 2: ...Fusion Client User Guide Rev 1 3 This page has been intentionally left blank ...
Page 7: ...Fusion Client User Guide Rev 1 3 ...
Page 32: ...FusionClient User Guide Rev 1 3 www kontron com 32 ...
Page 46: ...FusionClient User Guide Rev 1 3 www kontron com 46 flammable materials under the device ...
Page 48: ...FusionClient User Guide Rev 1 3 www kontron com 48 ...
Page 58: ...FusionClient User Guide Rev 1 3 www kontron com 58 ...
Page 70: ...FusionClient User Guide Rev 1 3 www kontron com 70 ...