FusionClient – User Guide (Rev. 1.3)
www.kontron.com
// 54
6.2.
Connecting to Power
Before using your system, you should first become familiar with the system
components and check that everything is properly connected. Following a proper
cabling procedure will prevent a false power-on condition, which could result in
unit operational failure.
The rated voltage range of the mains supply must correspond to the value on the
type label.
The FusionClient systems can be connected to a DC power source or optionally via an AC /DC powe
adapter to an AC main power. The DC power connector (Figure 12, pos. 1) is located on the bottom side of
the system.
6.2.1.
Behavior of the System when Connecting to Power
As soon as external power is applied to the input power connector (refer to Figure
12, pos. 1 and Figure 13) the FusionClient boots up and the operating system and
applications, where available, start immediately. Refer to 4.4.3.1 “Power Button
and Power LED”.
6.2.2.
DC Power Connection
Please observe the safety requirements given in chapter 1/ “General Safety Instructions for IT Equipment”.
The system must be connected only to a LPS (Limited Power Supply) DC mains
power supply complying with the requirements of EN 60950-1.
It must be ensured that the system can be powered ON and OFF via a readily
accessible two-pole disconnecting device that shall be incorporated in the building
installation wiring. It must be UL-listed and correspond to the required current and
voltage for the FusionClient (refer to the type label).
The system is only completely disconnected from the DC power source, when the
DC power cord is disconnected either from the power source or the unit. Therefore,
the DC power cord and its connectors must always remain easily accessible.
Ensure that a short-circuit (overcurrent) protection, is provided as part of the
building installation. Install only in accordance with national and local wiring
regulations.
When you install or replace the system the ground connection must always be
made first and disconnected last.
We recommend that the power cable should be the last cable attached to the
system.
To connect the FusionClient to a corresponding DC main power supply, please perform the following
steps:
1.
The wires used for power connections must be clearly marked (+/-/grounding) to ensure that they
will be proper connected to the DC connector of the FusionClient and to the main power source,
corresponding the signals marked (refer to Figure 13).
Summary of Contents for FusionClient FC 121
Page 1: ...FusionClient Fusion Client User Guide Rev 1 3 Doc ID 1060 3249 ...
Page 2: ...Fusion Client User Guide Rev 1 3 This page has been intentionally left blank ...
Page 7: ...Fusion Client User Guide Rev 1 3 ...
Page 32: ...FusionClient User Guide Rev 1 3 www kontron com 32 ...
Page 46: ...FusionClient User Guide Rev 1 3 www kontron com 46 flammable materials under the device ...
Page 48: ...FusionClient User Guide Rev 1 3 www kontron com 48 ...
Page 58: ...FusionClient User Guide Rev 1 3 www kontron com 58 ...
Page 70: ...FusionClient User Guide Rev 1 3 www kontron com 70 ...