Standalone DVR SEC-DVR304 User Manual
51
▲▼
Press these buttons to select the items.
ESC
Press this button to escape from this screen, and return to HDD Setup
display. If the Save dialog is shown, press
ENTER
to exit and save,
ESC
to exit without saving.
Name
Description
1
Duration
Response duration to define at most how long (in seconds) the
Alarm Out relay and the Buzzer will keep being triggered after
HDD failure is detected. Press
buttons to adjust the
value. (3 seconds - 60 minutes, discrete, ‘-‘ for ‘Forever’)
2
Alarm Out
To define which Alarm Output will be triggered when HDD
failure is detected. Press
buttons to select none (N/A) or
one of the Alarm Outputs (1-2).
3
Buzzer
To activate the internal Buzzer or not when HDD failure is
detected. Press
ENTER
or
to check/uncheck this item.
The default setting is “
” - checked.
4
Log
To log to event logs or not. Press ENTER or
to
check/uncheck this item. The default setting is “
”- checked.
5
To send the event e-mail to remote station or not. The e-mail
will be sent to the predefined receivers when the event is
triggered. Press
ENTER
or
to check/uncheck this item.
The default setting is “–” - unchecked.
6
Limited Period
Whether the HDD storage is for limited period or not. Press
ENTER or
to check/uncheck this item. The default setting
is “–” - No.
7
Retention Period
(hour)
The retention period of the HDD storage if Limited Period is
“
”. Please follow the Text Input method described in
chapter
5.1 Text Input
to modify this item. If this item is set as 0, it will
be treated as No Limited Period.