Standalone DVR SEC-DVR304 User Manual
50
6
SEQ
Click to clear the HDD.
Note
: If the HDD has not been formatted yet, it will be
formatted and partitioned with default record size, 30% for
Alarm record and 70% for Normal record. If it has been
formatted (and recorded) before, it will be partitioned according
to the Alarm Record Size (%) and Normal Record Size (%)
displayed on the screen, and the previously recorded contents
will all be cleared.
7
CALL
Press this button to physically format the selected HDD. A
confirmation dialog will be shown on the screen, press
ENTER
to confirm, or
ESC
to cancel. Please note that the recording
will be always optimized for performance & lifetime no matter
it’s for the first time or for the one hundredth time. The
formatting would take less than 1 minute. We strongly
recommend that the user use this physical format function to
format the HDD for the first time.
Note
: The HDD will be physically formatted and partitioned
with default record size, 30% for Alarm record and 70% for
Normal record. All the previously recorded contents will be
cleared.
7.6.6.2 Advanced HDD Setup
In
HDD
Setup display, press
SEQ
to call up
Advanced HDD Setup
display as
shown.
The HDD Failure Action in Advanced HDD Setup allows the administrator to
define how the system responds to the detected HDD failure, while the
Privacy settings allow the administrator to set the DVR to record for Limited
Period and the Retention Period of its HDD storage.
For software V6.13 or
above, the HDD Failure Action will be triggered if there’s no available
formatted HDD detected. When alarm record partition full, store to
normal record partition (and treated as normal video).
1
7
5
3
6
4
2