Standalone DVR SEC-DVR304 User Manual
46
Name
Description
1 Start Time Press to set the recording start time.
NOTE:
User can set up to a maximum of 16 different schedule segments. The beginning
of the new schedule segment represents the end of the previous schedule
segment. Thus, a warning dialog box will appear when two time schedule
segments overlap.
2 Alarm
Press
to set the recording criteria as audio (A), video (V) or both (A/V) when
the alarm is triggered.
“OFF” is newly added for alarm detection OFF.
3 Motion
Press
to set the recording criteria as audio (A), video (V) or both (A/V) when
the motion is detected.
“OFF” is newly added for alarm detection OFF.
4 Normal
Press
to set the recording criteria as audio (A), video (V) or both (A/V) under
normal recording circumstance.
NOTE: User can press COPY (
) to copy the setting of alarm 1 to all subsequent alarm settings.
NOTE: In a time segment, if both Alarm and Motion are set to “OFF”, the audio/video will be
treated as Normal unless there’s Video Loss.
7.6.6 HDD
In
Setup
display, press
▲▼
to change the highlighted option to
HDD
, and then
press
ENTER
to call up
HDD Setup
display as shown below.
In the surveillance applications, alarm video/audio is much more important than
normal video/audio. So, this digital video/audio recorder is designed to allow the
user to divide each HDD into alarm partition and normal partition. And, alarm
video/audio will be recorded in alarm partition, normal video/audio in normal
partition.
The HDD Setup allows the administrator to format/clear each HDD, set Alarm
Record size and Normal Record size of each HDD, and define the behaviors for
Alarm Record and Normal Record if it reaches the end of the last HDD in the
system.