Field Service Ver. 1.0 May 2006
6. Other
55
magicolor 7450
Maintenance
6.3.17
PH Interface Board (PWB-D)
1.
Remove the Front Cover.
2.
Remove the Transfer Belt.
3.
Remove two Screws [1], and remove
the Front Right Cover [2].
4.
Remove seven Screws [3], and
remove the Right Door Switch Assy
[4].
5.
Remove the Screw [5] each, and
remove the Imaging Unit contact
Assy [6] of each color.
[1]
[2]
4038F2C097DA
[3]
[3]
[4]
4038F2C098DA
[5]
[6]
4038F2C099DA