![Kongsberg EM 712 Installation Manual Download Page 181](http://html1.mh-extra.com/html/kongsberg/em-712/em-712_installation-manual_1992623181.webp)
401027/B
181
installation ................................................ 42
cavitation
acoustic noise.................................... 21–22, 26
transducer ................................................. 22
configuration.............................................. 69
dip switch setting ........................................ 69
performance ............................................ 152
1 pulse per second (1PPS) ............................ 138
connectors............................................... 127
signal characteristics .................................. 127
depth information ...................................... 154
gyro information ....................................... 154
heading information ................................... 154
motion information .................................... 155
position information ................................... 154
sonar room ................................................ 18
requirements for installation personnel ............... 16
Hydrographic Work Stationoutline dimensions
drawing .................................................. 93
introduction ............................................... 14
outline dimensions drawing ............................ 93
overview .................................................. 14
purpose .................................................... 14
designing, manufacturing and mounting the
steel conduit............................................. 44
minimum dimensions ................................... 44
CBMF board.............................................. 69
RIO-P board .............................................. 62
1 pulse per second (1PPS) ............................ 138
remote control Processing Unit ...................... 142
remote control Receiver Unit ........................ 147
remote control Transmitter Unit ..................... 145
Remote Control Unit (K-Rem)......................... 98
remote control using K-Rem ......................... 143
RS-232 serial cable .................................... 135
RS-422 serial cable .................................... 136
Hydrographic Work Station rear panel.............. 132
acoustic noise............................................. 24
origin .................................................... 103
vessel .................................................... 102
D
Serial Line adapter..................................... 137
depth information ...................................... 154
gyro information ....................................... 154
heading information ................................... 154
motion information .................................... 155
position information ................................... 154
datagram formats ...................................... 154
transducer ............................................... 161
ambient noise............................................. 28
bow thruster noise ....................................... 22
cavitation......................................... 21–22, 26
electrical noise ...................................... 26, 28
flow noise ............................................ 20, 27
Hydrographic Work Station ............................ 14
Hydrographic Work Station rear panel.............. 132
interference ............................................... 27
machinery noise.......................................... 26
origin in the vessel coordinate system .............. 103
propellers............................................. 22, 26
rattle noise ................................................ 27
Receiver Unit............................................. 13
self noise .................................................. 25
transducer ............................................ 12, 32
transducer blister......................................... 37
transducer gondola....................................... 36
Transmitter Unit.......................................... 13
vessel coordinate system.............................. 102
blister ...................................................... 37
computer outline dimensions drawing ................ 93
display ................................................... 159
Hydrographic Work Station .......................... 159
Hydrographic Work Station outline dimensions
drawing .................................................. 93
Processing Unit ........................................ 158
Processing Unit outline dimensions drawing ........ 92
rack installation kit ...................................... 95
Receiver Unit outline dimensions drawing........... 91
RX Unit ................................................. 159
specifications ........................................... 158
steel conduit .............................................. 44
transducer ............................................... 158
Transmitter Unit mounting bracket drawing ......... 90
Transmitter Unit outline dimensions drawing ........ 89
TX Unit ................................................. 159
dimensions drawing
transducer ................................... 71, 73, 75, 77
CBMF board.............................................. 69
Receiver Unit............................................. 66
RIO-P board .............................................. 62
environmental requirements.......................... 162
outline dimensions..................................... 159
power requirements.................................... 160
weight ................................................... 159
download from website .................................. 8
documents from website ................................. 8
1 pulse per second (1PPS) ............................ 138
casing ................................................. 85–88
computer outline dimensions........................... 93
Hydrographic Work Station outline
dimensions .............................................. 93
Index
Summary of Contents for EM 712
Page 71: ...401027 B 71 216148 EM 712 Transducer TX1 dimensions Drawing file ...
Page 72: ...72 401027 B Kongsberg EM 712 Installation manual ...
Page 73: ...401027 B 73 221048 EM 712 Transducer TX2 dimensions Drawing file ...
Page 74: ...74 401027 B Kongsberg EM 712 Installation manual ...
Page 75: ...401027 B 75 219621 EM 712 Transducer RX1 dimensions Drawing file ...
Page 76: ...76 401027 B Kongsberg EM 712 Installation manual ...
Page 77: ...401027 B 77 216146 EM 712 Transducer RX2 dimensions Drawing file ...
Page 78: ...78 401027 B Kongsberg EM 712 Installation manual ...
Page 79: ...401027 B 79 223137 EM 712 Transducer mounting frame 0 5 degrees Drawing file ...
Page 80: ...80 401027 B Kongsberg EM 712 Installation manual ...
Page 81: ...401027 B 81 223139 EM 712 Transducer mounting frame 1 degree Drawing file ...
Page 82: ...82 401027 B Kongsberg EM 712 Installation manual ...
Page 83: ...401027 B 83 223273 EM 712 Transducer mounting frame 2 degrees Drawing file ...
Page 84: ...84 401027 B Kongsberg EM 712 Installation manual ...
Page 85: ...401027 B 85 317812 EM 712 Casing w mounting frame 0 5 degrees Drawing file ...
Page 87: ...401027 B 87 375817 EM 712 Combined casing w mounting frame 1 degree Drawing file ...
Page 89: ...401027 B 89 396402 EM 712 Transmitter Unit dimensions Drawing file ...
Page 91: ...401027 B 91 396428 EM 712 Receiver Unit dimensions Drawing file ...
Page 92: ...92 401027 B 385422 Processing Unit dimensions Kongsberg EM 712 Installation manual ...
Page 93: ...401027 B 93 378828 Hydrographic Work Station dimensions Drawing file ...
Page 94: ...94 401027 B Kongsberg EM 712 Installation manual ...
Page 95: ...401027 B 95 371591 Rack installation kit dimenisons Drawing file ...
Page 96: ...96 401027 B 370275 Remote Control Unit K REM dimensions Kongsberg EM 712 Installation manual ...
Page 97: ...401027 B 97 Drawing file ...
Page 163: ...401027 B 163 Certificates IEC 60945 IACS E10 Technical specifications ...
Page 177: ...401027 B 177 7 Observe the handling rules for transducers Equipment handling ...
Page 188: ... 2018 Kongsberg Maritime ...