114
401027/B
Cable
Signal
From/To
C1
Display cable
From Hydrographic Work Station to display
This is a commercial cable. It is normally provided with the display.
C3
Keyboard
From Hydrographic Work Station to keyboard
This is a commercial cable. It is normally provided with the
keyboard.
C4
Mouse
From Hydrographic Work Station to mouse (or another similar
device)
This is a commercial cable. It is normally provided with the mouse.
C5
AC power cable
From display to AC power outlet
C7
AC power cable
From Hydrographic Work Station to AC power outlet
C8
Ground cable
From Hydrographic Work Station to vessel ground
C10
Ethernet cable
From Hydrographic Work Station to Processing Unit
See comment 4
C14
Serial cable
From Hydrographic Work Station to external device(s)
C18
Ethernet cable
Hydrographic Work Station \ Ship's local area network
C19
Ethernet cable
Hydrographic Work Station \ External device
C25
AC power
Ship supply / Processing Unit power supply
See comment 5
C26
Ground cable
From Processing Unit to vessel ground
C27
Control cable
From Processing Unit to remote control device
Remote on/off switch
If remote control is not used, a termination plug has to be inserted in
the Remote control plug on the Processing Unit. This plug is a 9 pin
D-SUB supplied with the Processing Unit.
Remote control, page 142
Remote Control using K-Rem, page 143
Dummy plug for not using remote control, page 144
C28
Control cable
From Processing Unit to synchronization device
External synchronization
External synchronisation, page 139
C29–C32
Serial cable
From Processing Unit to external device(s)
RS-232 serial line using three wires and RJ45 connector, page 135
RS-422 serial line using five wires and RJ45 connector, page 136
C33
Ethernet cable
From Processing Unit to external device(s)
Attitude Velocity sensor
C34
Coax cable
From Processing Unit to external device(s)
1 PPS (one pulse per second) clock synchronisation
Clock synchronisation (1PPS) using a coax cable, page 138
C36
Ethernet cable
Processing Unit internal connection
See comment 6
C40
Ethernet cable
Processing Unit / Transmitter Unit 1
See comment 7
C41
Ethernet cable
Processing Unit / Transmitter Unit 2
See comment 7
Kongsberg EM 712 Installation manual
Summary of Contents for EM 712
Page 71: ...401027 B 71 216148 EM 712 Transducer TX1 dimensions Drawing file ...
Page 72: ...72 401027 B Kongsberg EM 712 Installation manual ...
Page 73: ...401027 B 73 221048 EM 712 Transducer TX2 dimensions Drawing file ...
Page 74: ...74 401027 B Kongsberg EM 712 Installation manual ...
Page 75: ...401027 B 75 219621 EM 712 Transducer RX1 dimensions Drawing file ...
Page 76: ...76 401027 B Kongsberg EM 712 Installation manual ...
Page 77: ...401027 B 77 216146 EM 712 Transducer RX2 dimensions Drawing file ...
Page 78: ...78 401027 B Kongsberg EM 712 Installation manual ...
Page 79: ...401027 B 79 223137 EM 712 Transducer mounting frame 0 5 degrees Drawing file ...
Page 80: ...80 401027 B Kongsberg EM 712 Installation manual ...
Page 81: ...401027 B 81 223139 EM 712 Transducer mounting frame 1 degree Drawing file ...
Page 82: ...82 401027 B Kongsberg EM 712 Installation manual ...
Page 83: ...401027 B 83 223273 EM 712 Transducer mounting frame 2 degrees Drawing file ...
Page 84: ...84 401027 B Kongsberg EM 712 Installation manual ...
Page 85: ...401027 B 85 317812 EM 712 Casing w mounting frame 0 5 degrees Drawing file ...
Page 87: ...401027 B 87 375817 EM 712 Combined casing w mounting frame 1 degree Drawing file ...
Page 89: ...401027 B 89 396402 EM 712 Transmitter Unit dimensions Drawing file ...
Page 91: ...401027 B 91 396428 EM 712 Receiver Unit dimensions Drawing file ...
Page 92: ...92 401027 B 385422 Processing Unit dimensions Kongsberg EM 712 Installation manual ...
Page 93: ...401027 B 93 378828 Hydrographic Work Station dimensions Drawing file ...
Page 94: ...94 401027 B Kongsberg EM 712 Installation manual ...
Page 95: ...401027 B 95 371591 Rack installation kit dimenisons Drawing file ...
Page 96: ...96 401027 B 370275 Remote Control Unit K REM dimensions Kongsberg EM 712 Installation manual ...
Page 97: ...401027 B 97 Drawing file ...
Page 163: ...401027 B 163 Certificates IEC 60945 IACS E10 Technical specifications ...
Page 177: ...401027 B 177 7 Observe the handling rules for transducers Equipment handling ...
Page 188: ... 2018 Kongsberg Maritime ...