64
401027/B
Installing the Receiver Unit
The EM 712 Receiver Unit is normally located in a "sonar room" close to the transducer
arrays. The physical length of the cables limit the distance between the transducers and
the Receiver Unit.
Prerequisites
The standard length of the transducer cables are 15 metres. There is an option for cable
length of 25 metres.
The length of the cables are fixed. The cables can not be extended or shortened during
installation.
Free bulkhead space is required to mount the Receiver Unit.
Note
The installation shipyard must provide all necessary installation drawings.
If required, all drawings and documents must be approved by the vessel’s national
registry and corresponding maritime authority and/or classification society.
Such approval must be obtained before the installation can begin. The shipowner
and shipyard doing the installation are responsible for obtaining and paying for such
approval.
Context
The Receiver Unit is delivered as a complete cabinet with shock absorbers.
Mounting hole pattern for the Receiver Unit.
Procedure
1
Prepare the installation site.
a
Observe the general sonar room requirements.
b
Provide ample space around the cabinet to allow for inspection, maintenance
and parts replacement. Make sure that the space allows the cabinet door to be
fully dismounted for unobstructed access to its internal parts.
c
Verify that the installation does not cause problems with existing cabling,
ventilation ducts, piping etc. Check both sides of the bulkhead.
Kongsberg EM 712 Installation manual
Summary of Contents for EM 712
Page 71: ...401027 B 71 216148 EM 712 Transducer TX1 dimensions Drawing file ...
Page 72: ...72 401027 B Kongsberg EM 712 Installation manual ...
Page 73: ...401027 B 73 221048 EM 712 Transducer TX2 dimensions Drawing file ...
Page 74: ...74 401027 B Kongsberg EM 712 Installation manual ...
Page 75: ...401027 B 75 219621 EM 712 Transducer RX1 dimensions Drawing file ...
Page 76: ...76 401027 B Kongsberg EM 712 Installation manual ...
Page 77: ...401027 B 77 216146 EM 712 Transducer RX2 dimensions Drawing file ...
Page 78: ...78 401027 B Kongsberg EM 712 Installation manual ...
Page 79: ...401027 B 79 223137 EM 712 Transducer mounting frame 0 5 degrees Drawing file ...
Page 80: ...80 401027 B Kongsberg EM 712 Installation manual ...
Page 81: ...401027 B 81 223139 EM 712 Transducer mounting frame 1 degree Drawing file ...
Page 82: ...82 401027 B Kongsberg EM 712 Installation manual ...
Page 83: ...401027 B 83 223273 EM 712 Transducer mounting frame 2 degrees Drawing file ...
Page 84: ...84 401027 B Kongsberg EM 712 Installation manual ...
Page 85: ...401027 B 85 317812 EM 712 Casing w mounting frame 0 5 degrees Drawing file ...
Page 87: ...401027 B 87 375817 EM 712 Combined casing w mounting frame 1 degree Drawing file ...
Page 89: ...401027 B 89 396402 EM 712 Transmitter Unit dimensions Drawing file ...
Page 91: ...401027 B 91 396428 EM 712 Receiver Unit dimensions Drawing file ...
Page 92: ...92 401027 B 385422 Processing Unit dimensions Kongsberg EM 712 Installation manual ...
Page 93: ...401027 B 93 378828 Hydrographic Work Station dimensions Drawing file ...
Page 94: ...94 401027 B Kongsberg EM 712 Installation manual ...
Page 95: ...401027 B 95 371591 Rack installation kit dimenisons Drawing file ...
Page 96: ...96 401027 B 370275 Remote Control Unit K REM dimensions Kongsberg EM 712 Installation manual ...
Page 97: ...401027 B 97 Drawing file ...
Page 163: ...401027 B 163 Certificates IEC 60945 IACS E10 Technical specifications ...
Page 177: ...401027 B 177 7 Observe the handling rules for transducers Equipment handling ...
Page 188: ... 2018 Kongsberg Maritime ...