401027/B
161
Environmental requirements
These specifications summarize the temperature requirements and other environmental
standards for the EM 712 system.
transducers
•
Operational temperature
: -5 to +50 °C
•
Storage temperature
: -30 to +70 °C
•
Depth rating
: 250 m
Processing Unit
•
Operational temperature
: 0 to 50 °C
•
Storage temperature
: -30 to 70 °C
•
Relative humidity
: 5 to 95% relative non-condensing
•
Ingress protection (IP) rating
: IP22
•
Certificates
:
– IEC 60945:2002 and CORRIGENDUM 1:2008
– IACS E10:2006
TX Unit
•
Operational temperature
: 0 to +50°C
•
Storage temperature
: –30 to +70°C
•
Relative humidity
: 5 to 93% relative non-condensing
•
Ingress protection
: IP54
•
Vibration
:
–
Frequency range
: 5 to 150 Hz
–
Excitation level
: 1 g
•
Shock
:
–
Peak acceleration
: 15 g
–
Duration
: 11 ms
– Half sine pulse
•
Reference standards
:
– IEC 60945:2002 and CORRIGENDUM 1:2008
– IACS E10:2006
RX Unit
•
Operational temperature
: 0 to +50°C
Summary of Contents for EM 712
Page 71: ...401027 B 71 216148 EM 712 Transducer TX1 dimensions Drawing file ...
Page 72: ...72 401027 B Kongsberg EM 712 Installation manual ...
Page 73: ...401027 B 73 221048 EM 712 Transducer TX2 dimensions Drawing file ...
Page 74: ...74 401027 B Kongsberg EM 712 Installation manual ...
Page 75: ...401027 B 75 219621 EM 712 Transducer RX1 dimensions Drawing file ...
Page 76: ...76 401027 B Kongsberg EM 712 Installation manual ...
Page 77: ...401027 B 77 216146 EM 712 Transducer RX2 dimensions Drawing file ...
Page 78: ...78 401027 B Kongsberg EM 712 Installation manual ...
Page 79: ...401027 B 79 223137 EM 712 Transducer mounting frame 0 5 degrees Drawing file ...
Page 80: ...80 401027 B Kongsberg EM 712 Installation manual ...
Page 81: ...401027 B 81 223139 EM 712 Transducer mounting frame 1 degree Drawing file ...
Page 82: ...82 401027 B Kongsberg EM 712 Installation manual ...
Page 83: ...401027 B 83 223273 EM 712 Transducer mounting frame 2 degrees Drawing file ...
Page 84: ...84 401027 B Kongsberg EM 712 Installation manual ...
Page 85: ...401027 B 85 317812 EM 712 Casing w mounting frame 0 5 degrees Drawing file ...
Page 87: ...401027 B 87 375817 EM 712 Combined casing w mounting frame 1 degree Drawing file ...
Page 89: ...401027 B 89 396402 EM 712 Transmitter Unit dimensions Drawing file ...
Page 91: ...401027 B 91 396428 EM 712 Receiver Unit dimensions Drawing file ...
Page 92: ...92 401027 B 385422 Processing Unit dimensions Kongsberg EM 712 Installation manual ...
Page 93: ...401027 B 93 378828 Hydrographic Work Station dimensions Drawing file ...
Page 94: ...94 401027 B Kongsberg EM 712 Installation manual ...
Page 95: ...401027 B 95 371591 Rack installation kit dimenisons Drawing file ...
Page 96: ...96 401027 B 370275 Remote Control Unit K REM dimensions Kongsberg EM 712 Installation manual ...
Page 97: ...401027 B 97 Drawing file ...
Page 163: ...401027 B 163 Certificates IEC 60945 IACS E10 Technical specifications ...
Page 177: ...401027 B 177 7 Observe the handling rules for transducers Equipment handling ...