Operate the lever 3 to 4 times to the end of its stroke.
3) For the machine equipped with attachment control
pedal, set the attachment lock cover to FREE position
(F).
4) Operate the attachment repeatedly (approximately 10
times) to bleed the air completely from the attachment
circuit.
• For the machine equipped with attachment con-
trol pedal, operate the attachment control pedal
repeatedly with running the engine at low idle.
• For the machine equipped with proportional lever,
operate the proportional switch or breaker operat-
ing switch repeatedly with running the engine at low idle.
5) After completion of air bleeding, stop the engine.
Halt the machine for 5 minutes or more.
6) Start the engine again.
This discharges the air mixed in the oil in the hydraulic tank.
7) Check that there is no oil leakage and wipe off any oil that is spilled.