6.
Select “Manual Stationary Regeneration”, check again that
there is no person or combustible material around the ma-
chine, and then press the function switch “F4”.
If the machine needs to be moved again to secure safety,
move it to a safe place and repeat the procedure from step
1.
REMARK
• If you start the manual stationary regeneration, the engine speed increases gradually to the full speed.
It may take approximately 1 minute to start increasing the engine speed.
• After the function switch “F4” is pressed, the screen
shown in the figure may be displayed.
This indicates that the procedure from step 1 to 4 is
not performed correctly or there is trouble other than
KDPF soot accumulation abnormality.
Check that the engine is running normally, the lock
lever is in LOCK position, and the fuel control dial is in
Low idle (MIN) position, and then repeat the proce-
dure from step 6.
• The explanation sentence of the manual stationary re-
generation is displayed on the machine monitor in 4
separate paragraphs.
Press the function switch “F4”, and you can operate
the starting of regeneration.
Press the function switch “F3”, and the screen returns
to the standard screen.