EVERY 100 HOURS MAINTENANCE
METHOD FOR LUBRICATING
METHOD FOR LUBRICATING SWING SYSTEM
k
k
WARNING
Never swing the upper structure while greasing swing circle and swing pinion.
NOTICE
Perform greasing every 10 hours for the first 100 hours operation on a new machine.
Items to be prepared
Grease pump
1.
By using a grease pump, pump in grease through the
grease fittings shown by arrows.
(1) Swing pinion (1 place)
(2) Swing circle (1 place)
2.
Check visually that the greasing has been performed prop-
erly.
When greasing swing circle and swing pinion, swing the
upper structure little by little to change the position so that
the whole circumference will be greased.