PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
k
k
CAUTION
When canceling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
On the standard screen, if you press function switch “F4”,
“Aftertreatment Devices Regeneration” screen is dis-
played.
(If the screen is not displayed, operate function switches
“F6” and “F7” to display “Aftertreatment Devices Regener-
ation” screen.)
2.
On “Aftertreatment Devices Regeneration” screen, select
“Cancel of Regeneration Disable”, and then press function
switch “F4”.
“Cancel of Regeneration Disable” confirmation screen is
displayed.
3.
On “Regeneration Disable” confirmation screen, press
function switch “F4”.
The screen returns to “Aftertreatment Devices Regenera-
tion” screen, and the regeneration disable is canceled.
REMARK
If you press function switch “F3”, regeneration disable is
not canceled and screen returns to “Aftertreatment Devi-
ces Regeneration” screen.