OPERATION
DETAILED CONTROLS AND GAUGES
3-149
q
Accumulator for oil cooler circuit
There are six at the oil cooler end inside the power con-
tainer at the rear left of the machine.
REMARK
These accumulators are installed to protect the oil cooler from
abnormal pressure in the hydraulic circuit, and to improve the
reliability of the hydraulic equipment.
METHOD OF RELEASING PRESSURE IN ACCUMULATOR FOR HYDRAULIC CONTROL
CIRCUIT
3
A: Accumulator for cushioning the front idler
B: Accumulator for hydraulic control circuit
C: Accumulator for oil cooler circuit
1.
Lower the work equipment to the ground.
2.
Stop the engine.
3.
Turn the engine starting switch to the ON position.
4.
Move the lock lever (1) to the free position (F), and oper-
ate the work equipment control lever and the attachment
operation pedal (optional) back and forth and to the left and
right up to the stroke end in order to release pressure from
the respective control circuits.
5.
Start up the engine and stop it in a few seconds. And then
carry out the work 3 and 4 above.
6.
Continue the operation in Step 4 until the hissing noise of
pressure oil can no longer be heard. (Approx. 2 - 3 times)
7.
Push down lock lever (1) to locking position (L) to lock the
control lever and attachment operation pedal. However,
pressure cannot be released completely, so when remov-
ing the accumulator for the control circuit, loosen the screw
slowly and do not stand in the direction of hydraulic oil
spurting out.
Summary of Contents for PC2000-8 BACKHOE
Page 2: ......
Page 3: ...FOREWORD 11...
Page 27: ...SAFETY SAFETY LABELS 2 5 LOCATION OF SAFETY LABELS 2 9JH14979B...
Page 318: ...TROUBLES AND ACTIONS OPERATION 3 252...
Page 415: ...MAINTENANCE MAINTENANCE PROCEDURE 4 97...
Page 433: ...SPECIFICATIONS 15...
Page 436: ...SPECIFICATIONS SPECIFICATIONS 5 4...
Page 491: ...LOADING SHOVEL MAINTENANCE 7 17 q Greasing point chart...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 502: ...INDEX 8 6...
Page 503: ...COLOPHON 19...