![Kohler 11RMY Service Manual Download Page 79](http://html1.mh-extra.com/html/kohler/11rmy/11rmy_service-manual_1989770079.webp)
TP-5867 11/02
69
Section 8 Disassembly/Reassembly
9. Reinstall the enclosure panels. See Figure 8-17 or
Figure 8-18.
a. Install the non-service side housing panel.
b. Install the alternator end housing panel.
c. Install the generator set housing roof.
d. Reinstall the generator set housing service side
door.
A-358000C-B
1
2
3
4
5
R
POWER SYSTEM
1. Housing roof
2. Service side door
3. Battery compartment panel
4. Mounting pad
5. Alternator end housing panel
Figure 8-17
Generator Set Weather Housing
10. Return the generator set to operation.
a. Check that the generator set master switch is in
the OFF position.
b. Reconnect the generator set engine starting
battery, negative (--) lead last.
c. Reconnect power to the battery charger, if
equipped.
d. Turn on the fuel supply and check for leaks.
P-358000C-C
1
2
3
4
5
1. Housing roof
2. Service side door
3. Battery compartment panel
4. Mounting pad
5. Alternator end housing panel
Figure 8-18
Generator Set Sound Enclosure
Summary of Contents for 11RMY
Page 1: ...Industrial Generator Sets Models 8 5RMY 11RMY Controllers Relay TP 5867 11 02d Service...
Page 16: ...TP 5867 11 02 6 Section 1 Specifications Notes...
Page 32: ...TP 5867 11 02 22 Section 3 Troubleshooting Notes...
Page 40: ...TP 5867 11 02 30 Section 4 Controller Troubleshooting Notes...
Page 44: ...TP 5867 11 02 34 Section 5 Generator Relay Controller Troubleshooting Notes...
Page 68: ...TP 5867 11 02 58 Section 6 Component Testing and Adjustment Notes...
Page 72: ...TP 5867 11 02 62 Section 7 Generator Reconnection Notes...
Page 80: ...TP 5867 11 02 70 Section 8 Disassembly Reassembly Notes...
Page 82: ...TP 5867 11 02 72 Section 9 Wiring Diagrams Notes...
Page 87: ...TP 5867 11 02 77 Section 9 Diagrams and Drawings Relay Controller Schematic Diagram ADV 6524...
Page 96: ......
Page 97: ......