![Kohler 11RMY Service Manual Download Page 78](http://html1.mh-extra.com/html/kohler/11rmy/11rmy_service-manual_1989770078.webp)
TP-5867 11/02
68
Section 8 Disassembly/Reassembly
7. Install the exhaust system. See Figure 8-15.
a. Secure the lower portion of the exhaust duct to
the alternator exhaust support with 1/4-20
hardware.
b. Secure the engine exhaust muffler to the
engine.
Do not final tighten the mounting
hardware.
c. Secure the muffler mounting tab to the
alternator
exhaust
support
with
3/8-16
hardware.
d. Install the exhaust duct top.
Secure the
exhaust duct top to the exhaust duct bottom
with four 1/4-20 x 0.625 in. bolts and washers.
e. Torque the nuts securing the engine muffler
flange to the engine to 88 in. lb. (10 Nm).
TP56328
1
2
3
4
5
6
1. Exhaust duct, top
2. Engine muffler
3. 1/4-20 hardware
4. Exhaust duct, bottom
5. 1/4-20 x 0.625 in. bolts and 1/4 washers
6. 3/8-16 hardware
Figure 8-15
Exhaust Muffler Duct
8. Reconnect leads to the controller.
a. Insert the leads from the alternator assembly
into the convoluted conduit leading to the
controller.
b. Connect the speed sensor harness to the
controller.
See Figure 8-16 for the plug
location.
c. Route brush leads FP and FN into the controller
and connect them to the controller terminal
strip. See Figure 8-16.
d. Reconnect the alternator leads.
A-358076A-D
4
1
3
2
1. Speed sensor harness connection
2. L0 lead connection point
3. Circuit breaker connections
4. Brush leads FP and FN terminal block connections
Figure 8-16
ControllerTop View, Typical
Summary of Contents for 11RMY
Page 1: ...Industrial Generator Sets Models 8 5RMY 11RMY Controllers Relay TP 5867 11 02d Service...
Page 16: ...TP 5867 11 02 6 Section 1 Specifications Notes...
Page 32: ...TP 5867 11 02 22 Section 3 Troubleshooting Notes...
Page 40: ...TP 5867 11 02 30 Section 4 Controller Troubleshooting Notes...
Page 44: ...TP 5867 11 02 34 Section 5 Generator Relay Controller Troubleshooting Notes...
Page 68: ...TP 5867 11 02 58 Section 6 Component Testing and Adjustment Notes...
Page 72: ...TP 5867 11 02 62 Section 7 Generator Reconnection Notes...
Page 80: ...TP 5867 11 02 70 Section 8 Disassembly Reassembly Notes...
Page 82: ...TP 5867 11 02 72 Section 9 Wiring Diagrams Notes...
Page 87: ...TP 5867 11 02 77 Section 9 Diagrams and Drawings Relay Controller Schematic Diagram ADV 6524...
Page 96: ......
Page 97: ......