TP-5867 11/02
64
Section 8 Disassembly/Reassembly
3. Disconnect the alternator wiring. See Figure 8-3.
a. Disconnect alternator leads 1, 2, 3, and 4. Note
the locations of the lead connections for
reconnection later.
b. Disconnect brush leads FP and FN.
c. Disconnect the speed sensor harness.
4. Disconnect the exhaust system. See Figure 8-4.
a. Remove the four screws securing the top of the
exhaust duct.
b. Remove the engine exhaust muffler.
c. Remove the lower portion of the exhaust duct.
5. Remove the alternator end bracket.
a. Remove two bolts securing the alternator
vibromount mounting plate to the skid. See
Figure 8-5.
b. Raise the alternator end of the generator set
enough to place a thin block of wood beneath
the rear of the engine. See Figure 8-6.
A-358076A-D
4
1
3
2
1. Speed sensor harness connector
2. L0 lead connection point
3. Circuit breaker connections
4. Brush leads FP and FN terminal block connections
Figure 8-3
Controller Top View, Typical
A-358000A-B
1
2
3
1. Exhaust duct
2. Engine exhaust muffler
3. Exhaust duct screws
Figure 8-4
Exhaust Muffler Duct
A-358000A-B
1
1. Alternator vibromount mounting plate hardware
Figure 8-5
Generator Set, Right Side
A-358000A-B
1
1. Engine support block
Figure 8-6
Generator Set, Right Side
Summary of Contents for 11RMY
Page 1: ...Industrial Generator Sets Models 8 5RMY 11RMY Controllers Relay TP 5867 11 02d Service...
Page 16: ...TP 5867 11 02 6 Section 1 Specifications Notes...
Page 32: ...TP 5867 11 02 22 Section 3 Troubleshooting Notes...
Page 40: ...TP 5867 11 02 30 Section 4 Controller Troubleshooting Notes...
Page 44: ...TP 5867 11 02 34 Section 5 Generator Relay Controller Troubleshooting Notes...
Page 68: ...TP 5867 11 02 58 Section 6 Component Testing and Adjustment Notes...
Page 72: ...TP 5867 11 02 62 Section 7 Generator Reconnection Notes...
Page 80: ...TP 5867 11 02 70 Section 8 Disassembly Reassembly Notes...
Page 82: ...TP 5867 11 02 72 Section 9 Wiring Diagrams Notes...
Page 87: ...TP 5867 11 02 77 Section 9 Diagrams and Drawings Relay Controller Schematic Diagram ADV 6524...
Page 96: ......
Page 97: ......