3.5 If you suspect a failure
Symptom
Possible cause of trouble
Measure
Even with power on,
nothing is displayed.
Fuse is blown.
Power voltage is out of
specification (21.6 to 31.2
VDC)
Poor connection between
power cable and battery
Replace the fuse (See “3.3
Fuse Replacement
”, page
3-2.
Use a proper power as per
specification.
Check the connection
between power cable and
battery.
After starting up, nothing is
displayed
Poor connection between
transducer and Display unit
Failure of LCD display panel
Check the connection
between transducer and
Display unit.
Consult a repair shop or
sales agent.
Much interference noise
Improper installation of
transducer
Interference from the echo
sounder on other boats.
Check the installed position
of transducer (See “1.5
Installation of transducer”,
page 1-10.
Implement interference
rejection.
Display of
water temperature / Speed
is abnormal or not
displayed.
Poor connection of sensors
connectors
Input sources may be
abnormal.
Check the connection at
sensor connectors.
Check the input sources.
Display of present
location/course is
abnormal or not displayed.
Poor connection between
this unit and navigation
equipment
Check the connection
between this unit and
navigation equipment.
Summary of Contents for CVS-705D
Page 1: ......
Page 2: ......
Page 15: ...CVS 705D 707D Dimensions 0092607052 03 xiii Dimensions Display unit of CVS 705D Unit mm inch ...
Page 16: ...Dimensions CVS 705D 707D xiv 0092607052 03 Processor unit of CVS 707D Unit mm inch ...
Page 17: ...CVS 705D 707D Dimensions 0092607052 03 xv 17 inch LCD Monitor of CVS 707D Unit mm inch ...
Page 18: ...Dimensions CVS 705D 707D xvi 0092607052 03 Operation unit of CVS 705D 707D Unit mm inch ...
Page 20: ...Specifications CVS 705D 707D xviii 0092607052 03 This page intentionally left blank ...
Page 66: ...Chapter 2 Adjustment CVS 705D 707D 2 8 0092607052 03 This page intentionally left blank ...
Page 73: ......
Page 74: ......