Before you turn the unit on, check the following points to make sure the CVS-705D/707D
operates properly.
(1) Is the ship
’s supply voltage and current within the rated range?
(2) Is the transducer wiring normal? No wrong connections, no short circuits, etc.?
(3) Are the High and Low frequency transducers properly connected to their mating
terminals?
(4) Are the cables routed and connected properly?
Figure 1.16 An example of through-hull transducer installation
Transducers
Cable gland
Conduit pipe (SGP-1 1/2)
This pipe should be
extended to the draft line
or to the junction box.
TD Enclosure (Rectifying Tank)
Transducer
BOW
Protruding amount 300mm
Plate or rod to protect
knocking the nets or
ropes
Transducer