Chapter 1 Installation
CVS-705D/707D
1-10
0092607052-03
1.5 Installation of Operation unit
CVS-705D/707D Operation unit can be installed either on desk-top or flush-mounted.
Install by the following procedure
.
1.5.1 Desk-top installation
(1) Decide the location to install the Operation unit and keep the space for the maintenance
works as shown in Fig. 1.12.
(2) Mark the position where installation plinth is installed. (See Fig. 1.12)
(3) Remove 4 plastic corner guard caps of the Operation unit (These can be easily pulled out
upwards)
(4)
Fix the clamps to the Operation unit with the screw of 4M (4mm). Install the corner guard
caps removed in step (3).
(5)
Confirm that the clamps matches the marking position. If not matches, correct the marking
position
(6)
Install the clamps in the installing location (4 holes) and fix it with 4 tapping screws (4mm)
(M4 or pan-head). (Prepare 4 mm screws suitable for thickness of installing location.)
Fig. 1.11 Desk-top installation of Operation unit
Corner guard cap (4pcs)
Clamp (Right)
M4 Screw (4pcs)
M4 screw (4pcs)
Operation unit
Clamp (Left)
Unit: mm (inch)
Summary of Contents for CVS-705D
Page 1: ......
Page 2: ......
Page 15: ...CVS 705D 707D Dimensions 0092607052 03 xiii Dimensions Display unit of CVS 705D Unit mm inch ...
Page 16: ...Dimensions CVS 705D 707D xiv 0092607052 03 Processor unit of CVS 707D Unit mm inch ...
Page 17: ...CVS 705D 707D Dimensions 0092607052 03 xv 17 inch LCD Monitor of CVS 707D Unit mm inch ...
Page 18: ...Dimensions CVS 705D 707D xvi 0092607052 03 Operation unit of CVS 705D 707D Unit mm inch ...
Page 20: ...Specifications CVS 705D 707D xviii 0092607052 03 This page intentionally left blank ...
Page 66: ...Chapter 2 Adjustment CVS 705D 707D 2 8 0092607052 03 This page intentionally left blank ...
Page 73: ......
Page 74: ......