Configuration of Equipment
CVS-1410B
xii
0093114105-03
Type of transducer
No Specification Frequency Material
/
Length of
the cable
Mounting method
Beam width
(Right and left x
back and forth)
1
TDM-071
38 to 75 kHz
1 kW
Urethane
mold
15m
Ship’s bottom/
Ship’s side
38kHz
30°x20° ( -6dB)
75kHz
16°x 10° ( -6dB)
2
TDM-091D
42 to 65 kHz
130 to 210kHz
1 kW
Urethane
mold
15m
Ship’s bottom/
Ship’s side
42kHz
35° ( -6dB)
65kHz
22° ( -6dB)
130kHz
14° ( -6dB)
210kHz
8° ( -6dB)
Caution: For Inner-hull installation, an Inner-hull kit is necessary.