4a.
Take WIRES 10 and 11
off from RELAY K3.
4b.
Place the AMP-Y
CONNECTOR from the
INSTALLATION KIT onto PIN
6 of RELAY K3.
4c.
Place WIRES 10 and 11
onto the open ends of the
AMP-Y CONNECTOR.
4d.
Place the INSULATED
AMP CONNECTOR from the
INSTALLATION KIT onto PIN
9 of RELAY K3. This is a
safety precaution, that PIN 9,
still connected to 120VAC,
cannot be touched.
4e.
Place a WIRE TIE around
WIRES 10 and 11 just behind
the 2 AMP CONNECTORS.
4f.
Fix WIRES 10 and 11 with
an additional WIRE TIE to the
existing harness.
PROCESSOR START
SIGNAL
The PROCESSOR START SIGNAL to the M6B comes from CONNECTOR A4X17 on
PCB A4 (SBS). Ensure that PIN 2 of this CONNECTOR re9 Volts from the
M6B. If +9 Volts are applied to PIN 1 of this CONNECTOR, the OPTOCOUPLER U8 on
PCB A4 (SBS) would not generate the PROCESSOR START SIGNAL.
figure 7-5
II 3066-2
10/98
7-6
KODAK AG, Stuttgart
Summary of Contents for MULTILOADER 700 PLUS