FUSE IN THE IEC CONNECTOR
LINE VOLTAGE
EUROPE
USA / CANADA
OTHER
COUNTRIES
100 V
—-
—-
T 3.15A (IEC)
120 V
—-
T 2A ( SLOW
BLOW)
—-
220 V
T 3.15A (IEC)
—-
T 3.15A (IEC)
230 V
T 3.15A (IEC)
—-
T 3.15A (IEC)
240 V
T 3.15A (IEC)
T 2A (SLOW
BLOW)
T 3.15A (IEC)
COVER PLATE
A COVER PLATE has to be mounted to the housing of the POWER SUPPLY. This PLATE
prevents parts from falling onto PCB A3/4 during a maintenance call or when the operator
opens the SBS TOP COVER for any reason. The COVER PLATE is mounted with 2 PLASTIC
SCREWS (M4x10) to the POWER SUPPLY COVER.
DFT JUMPER
This JUMPER terminates the WIRING HARNESS to the DFT. It simulates a closed
DARK-ROOM FEED TRAY. The SBS is delivered with this JUMPER. If a DFT is to be
installed, this JUMPER is replaced with the SOCKET from the DFT cable. If no DFT is
installed AND if this JUMPER is missing, the SBS BUZZER will sound permanently.
BRIGHTNESS CONTROL PCB
NOTE
Install this PCB only if the SBS is used with a DFT
This PCB allows to control the brightness of the DFT INDICATOR LED in the DARKROOM.
To install it, take off CONNECTOR A4X30, plug in the CONNECTOR of the BRIGHTNESS
CONTROL PCB instead and plug in the CONNECTOR A4X30 to the SOCKET on the
BRIGHTNESS CONTROL PCB. See the layout of PCB A4 on the next page.
II 3066-2
10/98
5-4
KODAK AG, Stuttgart
Summary of Contents for MULTILOADER 700 PLUS
Page 12: ...II 3066 2 10 98 1 8 KODAK AG Stuttgart...
Page 22: ...II 3066 2 10 98 4 2 KODAK AG Stuttgart...
Page 28: ...II 3066 2 10 98 5 6 KODAK AG Stuttgart...
Page 48: ...II 3066 2 10 98 7 16 KODAK AG Stuttgart...
Page 54: ...II 3066 2 10 98 8 6 KODAK AG Stuttgart...
Page 72: ...II 3066 2 10 98 12 8 KODAK AG Stuttgart...
Page 76: ...II 3066 2 10 98 13 4 KODAK AG Stuttgart...
Page 90: ...II 3066 2 10 98 14 14 KODAK AG Stuttgart...