Electric motors Size 63 - 225 ATEX / IECEx
Technical data
2021-05-31
21
Pos : 3. 10 /KN 2006-SM /nL---------- Abschnitts ende ---------- @ 8\ mod_1141997892953_0.doc @ 75471
s: 3.11 /KN 2006-Pr ojekt e/H erf order Elektr omotor en- Wer ke/Technisc he Daten/ ATEX/ 009 1. 1 Ex-Kennz eic hnung @ 60\ mod_1203497200012_1.doc @ 1039729
3.3 Explosion protection marking
EXPLOSION PROTECTION!
acc. to ATEX directive 2014/34/EU
standard EN 60079 or IECEx / standard IEC 60079
Marking acc. to ATEX
– size 63
II 2G Ex db IIC T4
– T6 Gb or Ex db e IIC T4 – T6 Gb
Oder II 2G Ex db IIC T4
– T6 Gb or Ex db eb IIC T4 – T6 Gb
II 2G Ex db IIB T4
– T6 Gb or Ex db e IIB T4 – T6 Gb
Oder II 2G Ex db IIB T4
– T6 Gb or Ex db eb IIB T4 – T6 Gb
II 2D Ex tb IIIC T 135
– 85°C Db
II 2D Ex tb IIIB T 135
– 85°C Db
Marking acc. to IECEx
– size 63
Ex db IIC T4
– T6 Gb or Ex db e IIC T4 – T6 Gb
or Ex db IIC T4
– T6 Gb or Ex db eb IIC T4 – T6 Gb
Ex db IIB T4
– T6 Gb or Ex db e IIB T4 – T6 Gb
or Ex db IIB T4
– T6 Gb or Ex db eb IIB T4 – T6 Gb
Ex tb IIIC T 135
– 85°C Db
Ex tb IIIB T 135
– 85°C Db
Marking acc. to ATEX
– sizes 71 -225
II 2G Ex db IIC T1
– T6 Gb or Ex db eb IIC T1 – T6 Gb
or II 2G Ex d IIC T1
– T6 Gb or Ex de IIC T1 – T6 Gb
II 2G Ex db IIB T1
– T6 Gb or Ex db eb IIB T1 – T6 Gb
or II 2G Ex d IIB T1
– T6 Gb or Ex de IIB T1 – T6 Gb
II 2D Ex tb IIIC T 200
– 85°C Db
Marking acc. to IECEx
– sizes 71 -225
Ex db IIC T1
– T6 Gb or Ex db eb IIC T1 – T6 Gb
or Ex d IIC T1
– T6 Gb or Ex de IIC T1 – T6 Gb
Ex db IIB T1
– T6 Gb or Ex db eb IIB T1 – T6 Gb
or Ex d IIB T1
– T6 Gb or Ex de IIB T1 – T6 Gb
Ex tb IIIC T 200
– 85°C Db