58
TROUBLESHOOTING
INSUFFICIENT DRAUGHT.
DIFFICULT FLUE GAS EVACUATION.
FLUE GAS ESCAPING INTO THE ROOM.
ELEMENTS TO CHECK
ORIGIN
External air vent
Inexistent;
Shutter closed;
Accidental obstruction;
Insufficient cross section.
Air vent (pipe)
Insufficient cross section.
Combustion air damper
Closed or badly adjusted.
Smoke damper
Closed or badly adjusted.
Wood
Excessive humidity.
Flue
Hood fitting/flue gas
channel
Insufficient cross section;
Insufficient height;
Accidental obstructions;
Periodical cleaning not performed;
Heat insulation or insulation insufficient or
inexistent;
Use of unsuitable materials;
Heat insulation or insulation absent or
insufficient;
Inadequate cross section (square or
rectangular) or incorrect dimensioning;
Narrowing or presence of obstacles to the
flow of flue gas;
Accidental obstructions;
Infiltrations of parasite air due to the use of
materials not impermeable to gas and liquids;
Insufficient height.
Chimney
Outlet height in reflow zone;
Close to or adjoining other chimneys;
Vicinity of obstacles, both natural and artificial;
Obstruction ( e.g.: birds nests);
Inadequate chimney pot shape;
Insufficient emission cross section.
Summary of Contents for K top
Page 1: ...INSTALLATION USE AND MAINTENANCE USEFUL ADVICE Heating cooker Heating stove User guide EN...
Page 2: ...2...
Page 5: ...5 HEATING COOKERS and HEATING STOVES models K top KP top and models TS top TSP top S R L...
Page 15: ...15 Top view of heating stove 600 665 622 275 515 170 150...
Page 49: ...49 Loosen the two hex screws on the inspection vent 1 2...
Page 50: ...50 Remove the vent as shown in the diagram and remove any deposits under the oven...
Page 63: ...63...